|
Dawley Inc
electroencephalogram eeg data ![]() Electroencephalogram Eeg Data, supplied by Dawley Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/2+channel+eeg+telemetry/pmc12696922-239-0-13 Average 86 stars, based on 1 article reviews
electroencephalogram eeg data - by Bioz Stars,
2026-10
86/100 stars
|
Buy from Supplier |
|
Compumedics Neuroscan
electroencephalogram eeg data ![]() Electroencephalogram Eeg Data, supplied by Compumedics Neuroscan, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/data+eeg/pm41038592-144-0-7 Average 86 stars, based on 1 article reviews
electroencephalogram eeg data - by Bioz Stars,
2026-10
86/100 stars
|
Buy from Supplier |
|
Welcony
electroencephalogram eeg data ![]() Electroencephalogram Eeg Data, supplied by Welcony, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/Geodesic+EEG+System/pm41015087-133-4-18 Average 96 stars, based on 1 article reviews
electroencephalogram eeg data - by Bioz Stars,
2026-10
96/100 stars
|
Buy from Supplier |
|
brain products gmbh
electroencephalogram (eeg) data ![]() Electroencephalogram (Eeg) Data, supplied by brain products gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/eeg+data/pm37689832-103-1-12 Average 90 stars, based on 1 article reviews
electroencephalogram (eeg) data - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Johns Hopkins HealthCare
electroencephalogram (eeg) data ![]() Electroencephalogram (Eeg) Data, supplied by Johns Hopkins HealthCare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/ecg/pm37422278-6-65-36 Average 90 stars, based on 1 article reviews
electroencephalogram (eeg) data - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
MathWorks Inc
electroencephalogram data analysis ![]() Electroencephalogram Data Analysis, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/Database+Toolbox/pmc09530600-55-1-10 Average 96 stars, based on 1 article reviews
electroencephalogram data analysis - by Bioz Stars,
2026-10
96/100 stars
|
Buy from Supplier |
|
MathWorks Inc
electroencephalogram data ![]() Electroencephalogram Data, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/electroencephalogram+eeg+data/Database+Toolbox/pmc08869925-199-0-12 Average 96 stars, based on 1 article reviews
electroencephalogram data - by Bioz Stars,
2026-10
96/100 stars
|
Buy from Supplier |
Journal: Particle and Fibre Toxicology
Article Title: Sleep disruption from inhalation of biomass smoke: a basis for coincident hypertension?
doi: 10.1186/s12989-025-00650-9
Figure Lengend Snippet: Exposure and Monitoring Protocol. Rats were implanted with a telemetry device capable of simultaneously monitoring the electroencephalogram, aortic blood pressure, activity and core body temperature. Sleep, blood pressure, activity, and core body temperature were recorded in male and female Sprague Dawley rats prior to (8 h; 11:00 AM to 7:00 PM), during (1 h; ~9:30 AM to 10:30 AM), and after (8 h; 11:00 AM to 7:00 PM) a single 1-hour exposure to filtered air or eucalyptus smoke. The EEG was used to analyze sleep quality and architecture and determine sleep staging. The blood pressure trace was used to analyze blood pressure and derive heart rate and heart rate variability determinations
Article Snippet:
Techniques: Activity Assay
Journal: Particle and Fibre Toxicology
Article Title: Sleep disruption from inhalation of biomass smoke: a basis for coincident hypertension?
doi: 10.1186/s12989-025-00650-9
Figure Lengend Snippet: Eucalyptus smoke exposure significantly alters sleep and wake duration during exposure. Electroencephalogram (EEG) data were recorded using implantable telemetry in male and female Sprague Dawley rats to measure the polysomnography parameters rapid-eye-movement (REM) sleep, non-rapid eye movement (NREM) sleep, and wake prior to (8 h; 11:00 AM to 7:00 PM), during (1 h; 9:30 to 10:30 AM), and after (8 h; 11:00 AM to 7:00 PM) filtered air or eucalyptus smoke exposure. Data were separated by sex. The following measurements were collected: ( a ) REM duration during exposure, 5-min intervals ( b ) mean REM duration during the first 30-minutes during exposure ( c ) REM duration, post- minus pre-exposure ( d ) NREM duration during exposure, 5-min intervals ( e ) mean NREM duration during the first 30-minutes during exposure ( f ) NREM duration, post- minus- pre-exposure ( g ) wake duration during exposure, 5-min intervals ( h ) mean wake duration during the first 30-minutes during exposure and ( i ) wake duration, post- minus pre-exposure. Data are mean ± SEM and were analyzed by a generalized linear mixed model for figures (a, c, d, f, g, and I), or by unpaired Student’s t-test (figures b, e and h.). Data during exposure are reported in 5-min intervals; percent change data after exposure are reported in 1-hr intervals. * p < 0.05, ** p < 0.01. n = 8 per group
Article Snippet:
Techniques:
Journal: Particle and Fibre Toxicology
Article Title: Sleep disruption from inhalation of biomass smoke: a basis for coincident hypertension?
doi: 10.1186/s12989-025-00650-9
Figure Lengend Snippet: Eucalyptus smoke exposure significantly impacts rapid-eye-movement (REM) sleep in males. Electroencephalogram (EEG) data were recorded using implantable telemetry in male and female Sprague Dawley rats to measure REM sleep prior to (8 hrs; 11:00 AM to 7:00 PM), during (1 hr; 9:30 AM to 10:30 AM), and after (8 hrs; 11:00 AM to 7:00 PM) filtered air or eucalyptus smoke exposure. Data were separated by sex. The following measurements were collected: (a) Total REM bouts during exposure (b) percent change in total REM bouts post-exposure (relative to pre-exposure) over 8 hrs (c) REM bout duration during exposure (d) percent change in REM bout duration post-exposure (relative to pre-exposure) over 8 hrs (e) total REM time during 1-hr exposure and (f) percent change in total REM time post-exposure (relative to pre-exposure) over 8 hrs. Data are mean ± SEM and were analyzed by unpaired Student’s t-test. Data during exposure are reported in 5-min intervals; percent change data after exposure are reported in 1-hr intervals. *p < 0.05, **p < 0.01. n = 8 per group
Article Snippet:
Techniques:
Journal: Particle and Fibre Toxicology
Article Title: Sleep disruption from inhalation of biomass smoke: a basis for coincident hypertension?
doi: 10.1186/s12989-025-00650-9
Figure Lengend Snippet: Eucalyptus smoke exposure significantly alters theta and alpha power. Electroencephalogram (EEG) data were recorded using implantable telemetry in male and female Sprague Dawley rats to measure polysomnography. Normalized discrete fast Fourier transform was used to evaluate spectral power for rapid-eye movement (REM) sleep, non-rapid-eye movement (NREM) sleep, and wake prior to (8 h; 11:00 AM to 7:00 PM), during (1 h; 9:30 to 10:30 AM), and after (8 h; 11:00 AM to 7:00 PM) filtered air or eucalyptus smoke exposure. Data were separated by sex. The following measurements were collected: ( a ) female REM spectral power during exposure (Note: not enough REM data in males to allow for REM spectral analysis) ( b ) NREM spectral power during exposure ( c ) Wake spectral power during exposure ( d ) female theta power, 4–8 Hz during exposure ( e ) delta power, 0.5–4 Hz during exposure ( f ) alpha power, 8–12 Hz during exposure ( g ) percent change post-exposure (relative to pre-exposure) in REM theta power ( h ) percent change post-exposure (relative to pre-exposure) in NREM delta power ( i ) percent change post-exposure (relative to pre-exposure) in wake alpha power. Data are mean ± SEM and analyzed by two-way repeated measures ANOVA with Šídák’s multiple comparisons test. Data during exposure are reported are reported for each frequency ; percent change data after exposure are also reported for each frequency . * p < 0.05, ** p < 0.01, **** p < 0.0001. n = 8 per group
Article Snippet:
Techniques:
Journal: Brain Sciences
Article Title: The Functional Interactions between Cortical Regions through Theta-Gamma Coupling during Resting-State and a Visual Working Memory Task
doi: 10.3390/brainsci12020274
Figure Lengend Snippet: A schematic of the eyes-closed resting electroencephalography (EEG) and memory test protocol. The resting-state and retention interval (red squares) were used for analysis in the study.
Article Snippet:
Techniques: